PIPA

Inspection Report 424586-v1

ID:
424586-v1
Expiry Date:
12 June 2026
Status:
Pass
Inspection Body:
P & J Entertainments
Tag No:
52051
Device Type:
Obstacle Course
Serial Number:
P48233_A
Item Status / Details Notes
Report Details

This is an inspection of an inflatable device which has been completed under the scheme rules of the PIPA Testing Scheme Limited.

Creation Date:
11/06/2025
 
Inspection Date:
11/06/2025
 
Place of Inspection:
Uckfield
 
Inspector:
19: John Quaif
 
Structure version:
202505
 
Tested for Indoor Use Only:
No
Device

Information about the device can be found below.

PIPA Reference Number:
52051
 
Tag Number:
52051
 
Type:
Obstacle Course
 
Name:
2 PART ENERGY ASSAULT COURSE RED & BLACK
 
Manufacturer:
Airquee Ltd
 
Serial Number:
P48233_A
 
Date Manufactured:
Unknown
 
Images - Each side of the device:
Label and markings:
Label
Is the manufacturer's operation manual present?:
Pass
1) The controller must obtain a copy of the operations manual by the next inspection, operating manuals provide vital information on how you should setup, maintain and care for your device. 2) Please see the QR code located on the blower tube for a copy of the manual. 3) Hard copy of operations manual presented at time of inspection.
Structure

This section of the report contains important structural information about your device. How a device has been designed and structured is a very important part of device safety.

Length:
12.3m
Width:
3.2m
Height:
3.3m
Bed Panel Width:
0.44m
Trough Depth:
Pass
0.10m
10/44
Seam Security:
Pass
No issues
The size of the stitching is between 3mm and 8mm:
Pass
3-5 mm
Internal wall Heights:
Pass
1.5m
Enclosed
Are the walls able to contain the intended users?:
Pass
Open Side Fall off Height:
Pass
0.45m
Grounding:
Pass
85kg
85kg
Stability:
Pass
Stable
Entrapment:
Pass
None Present
Sharp Angles or Hard Surfaces:
Pass
None
Number of Zips on unit? Is the toggle covered and moving freely?:
Pass
6
Covered
Window Integrity:
Pass
No issues
Are Nets Present?:
Yes
Ceiling Netting < 8mm:
Pass
Manufacturer
Walls / Windows Netting < 30mm:
Pass
Netted Side windows
Are clamber nets present?:
No
Air Loss Points:
Pass
No significa
Type of Artwork:
Materials

This covers the materials your device has been made from. Although the structure won’t change over time the condition of materials will due to wear and tear and exposure to users and the elements.

Fabric Material and Condition:
Pass
Manufacturer Manufacturer label states it meets BSEN14960.
Thread Condition:
Pass
Non rot Manufacturer label states it meets BSEN14960.
Material Fire Retardancy:
Pass
Manufacturer Manufacturer label states it meets BSEN14960.
De-lamination of PVC:
Pass
No issues
Anchorage

A vital part of safe inflatable device operation is appropriate anchoring – especially when devices are used outdoors.

Tested for Indoor Use Only:
No
Number of high level anchors:
0
Calculated Required No. of Anchor Points:
16
Total No. of Anchor Points:
Pass
16
Anchor Point Integrity, Location and Angle:
Pass
Anchor Point Accessories:
Pass
Ground pegs should be minimum 16mm x 380mm and within 25mm of ground level. Where weights are use outside for anchorage each anchor should have a minimum 163kg of weights applied, when used indoors sufficient weight should be used to give stability to the unit to prevent form movement, care should be taken to not create additional hazards from tripping or hard objects within the impact area of the device.
Anchor Description:
Pass
Pvc triangle
Are Ropes Present As Part of Anchorage:
No
Area & surround
Play Area m²:
12m2
Blowers

By definition inflatable devices covered by the PIPA Testing Scheme will use blowers. Blowers are fundamental to the operation of the device and will be checked both mechanically and electrically by your inspector. Note that is common for blowers to be moved between devices as, in many cases, it's not possible to always ensure a specific blower will always be used with a specific device. If blowers are swapped or replaced, they must be of the same design and power as used when the device was inspected.

Air Pressure:
Pass
1.2kPa
The minimum operating pressure shall be 1kpa unless advised otherwise in the operations manual.
Number of Blowers:
2
PAT Test - Is there a valid PAT test result within the past 12 months?:
Pass
Date of PAT Test:
11/06/2025
Inspection of the blower's inlet guard, outlet guard, non-return valve, impeller and electrical cable:
Pass
Blower Manufacturer:
Gibbons
Blower Model Reference:
5006
Blower Serial Number:
Zn146848
Blower Power / Size:
1.5hp
CE/UKCA Mark:
Pass
Blower Distance:
Pass
1.25m
PAT Test - Is there a valid PAT test result within the past 12 months?:
Pass
Date of PAT Test:
11/06/2025
Inspection of the blower's inlet guard, outlet guard, non-return valve, impeller and electrical cable:
Pass
Blower Manufacturer:
Gibbons
Blower Model Reference:
5005d
Blower Serial Number:
Vc291265
Blower Power / Size:
1.5hp
CE/UKCA Mark:
Pass
Blower Distance:
Pass
1.25m
Entrance, exits & evacuation

The entrance or exit of an inflatable is important to ensure safe access and evacuation. It also has design features to help reduce the risks to users on the device.

Evacuation Time:
Pass
30Seconds
No issues
Is the device considered to be an enclosed unit?:
No
Does the device have a step?:
Yes
Adjacent Platform Height:
0.61m
Length of Step :
Pass
1.0m
0.61m/1m
Slides

Slides are a particularly fun feature of an inflatable device and there are critical dimensions required to ensure safe operation.

Number of Slides:
1
Platform Height:
2.3m
Platform Wall Height:
Pass
0.9m
First Meter Wall Height:
Pass
0.9m
Slide Wall Height:
Pass
0.9m
Slide Sheet:
Pass
SLIDING MAT.
Run Out:
Pass
1.6m
1.6
Platform Roof Fitted:
Pass
Is the method of access to the slide using foam steps?:
Yes
Users

Understanding the height and number of users is vital to safe operation of an inflatable device. This should have been specified by the device manufacturer, but the inspector will check the manufacturers recommendations based on device dimensions and appropriate standards.

Max Number of Users of Height up to 1.0m:
12
Max Number of Users of Height up to 1.2m:
12
Max Number of Users of Height up to 1.5m:
12
Max Number of Users of Height up to 1.8m:
10
Custom Max User Height:
Notes

These are final notes sections for the relate to the report and are particularly important to pay attention to if present. Risk Assessments contain important operational information that must be noted and acted on to ensure safe play. Your inspector may also provide other Advisory Notes related to maintenance or operation over the next 12 months

Additional Notes:
Please use all the anchor points to secure the unit to the ground Do not use in wind speed above 24mph or 38kph Please put safety mats around the front step and slide
Risk Assessment Notes:
Repairs needed to pass inspection:
Advisory items :
I confirm that this inflatable obstacle course device has been inspected in accordance with the PIPA scheme rules, and where it is applicable, it meets the requirements of BS EN 14960. All details contained within this inspection report are a true representation of what I found and observed during my inspection process.