This is an inspection of an inflatable device which has been completed under the scheme rules of the PIPA Testing Scheme Limited.
Inspection Report 430617-v1 |
|
|
| Item | Status / Details | Notes | |
|---|---|---|---|
| Report Details | |||
|
This is an inspection of an inflatable device which has been completed under the scheme rules of the PIPA Testing Scheme Limited. |
|||
|
Creation Date:
|
17/10/2025
|
|
|
|
Inspection Date:
|
17/10/2025
|
|
|
|
Place of Inspection:
|
Maidenhead (Cox green)
|
|
|
|
Inspector:
|
17: Adam Janes
|
|
|
|
Structure version:
|
202505
|
|
|
|
Tested for Indoor Use Only:
|
No
|
|
|
| Device | |||||||
|---|---|---|---|---|---|---|---|
|
Information about the device can be found below. |
|||||||
|
PIPA Reference Number:
|
44104
|
|
|||||
|
Tag Number:
|
44104
|
|
|||||
|
Type:
|
Bounce/Slide Combo
|
|
|||||
|
Name:
|
farm yard bounce and slide
|
|
|||||
|
Manufacturer:
|
Hoppborgsgruppen
|
|
|||||
|
Serial Number:
|
44104
|
|
|||||
|
Date Manufactured:
|
Unknown
|
|
|||||
|
Images - Each side of the device:
|
|
||||||
|
|||||||
|
Label and markings:
|
|
||||||
|
Is the manufacturer's operation manual present?:
|
Pass
|
|
|||||
| Structure | |||
|---|---|---|---|
|
This section of the report contains important structural information about your device. How a device has been designed and structured is a very important part of device safety. |
|||
|
Length:
|
6.4m
|
|
|
|
Width:
|
4.6m
|
|
|
|
Height:
|
4.1m
|
|
|
|
Bed Panel Width:
|
0.6m
|
|
|
|
Trough Depth:
|
Pass
|
0.08m
|
|
|
Seam Security:
|
Pass
|
|
|
|
The size of the stitching is between 3mm and 8mm:
|
Pass
|
|
|
|
Internal wall Heights:
|
Pass
|
1.2m
|
|
|
Are the walls able to contain the intended users?:
|
Pass
|
|
|
|
Open Side Fall off Height:
|
Pass
|
0.5m
|
.5m
|
|
Grounding:
|
Pass
|
85kg
|
|
|
Stability:
|
Pass
|
|
|
|
Entrapment:
|
Pass
|
|
|
|
Sharp Angles or Hard Surfaces:
|
Pass
|
|
|
|
Number of Zips on unit? Is the toggle covered and moving freely?:
|
Pass
|
3
|
|
|
Window Integrity:
|
Pass
|
|
|
|
Are Nets Present?:
|
Yes
|
|
|
|
Ceiling Netting < 8mm:
|
|
||
|
Walls / Windows Netting < 30mm:
|
Pass
|
|
|
|
Are clamber nets present?:
|
No
|
|
|
|
Air Loss Points:
|
Pass
|
|
|
|
Type of Artwork:
|
Pass
|
Print
|
|
| Materials | |||
|---|---|---|---|
|
This covers the materials your device has been made from. Although the structure won’t change over time the condition of materials will due to wear and tear and exposure to users and the elements. |
|||
|
Fabric Material and Condition:
|
Pass
|
|
|
|
Thread Condition:
|
Pass
|
|
|
|
Material Fire Retardancy:
|
Pass
|
|
|
|
De-lamination of PVC:
|
Pass
|
|
|
| Anchorage | |||
|---|---|---|---|
|
A vital part of safe inflatable device operation is appropriate anchoring – especially when devices are used outdoors. |
|||
|
Tested for Indoor Use Only:
|
No
|
|
|
|
Number of high level anchors:
|
0
|
|
|
|
Calculated Required No. of Anchor Points:
|
8
|
|
|
|
Total No. of Anchor Points:
|
Pass
|
10
|
|
|
Anchor Point Integrity, Location and Angle:
|
Pass
|
|
|
|
Anchor Point Accessories:
|
Pass
|
|
|
|
Anchor Description:
|
Pass
|
PVC d
|
|
|
Are Ropes Present As Part of Anchorage:
|
No
|
|
|
| Area & surround | |||
|---|---|---|---|
|
Play Area m²:
|
10.2m²
|
|
|
| Blowers | |||
|---|---|---|---|
|
By definition inflatable devices covered by the PIPA Testing Scheme will use blowers. Blowers are fundamental to the operation of the device and will be checked both mechanically and electrically by your inspector. Note that is common for blowers to be moved between devices as, in many cases, it's not possible to always ensure a specific blower will always be used with a specific device. If blowers are swapped or replaced, they must be of the same design and power as used when the device was inspected. |
|||
|
Air Pressure:
|
Pass
|
1.2kPa
|
|
|
Number of Blowers:
|
1
|
|
|
|
PAT Test - Is there a valid PAT test result within the past 12 months?:
|
Pass
|
|
|
|
Date of PAT Test:
|
17/10/2025
|
|
|
|
Inspection of the blower's inlet guard, outlet guard, non-return valve, impeller and electrical cable:
|
Pass
|
|
|
|
Blower Manufacturer:
|
Huwaei
|
|
|
|
Blower Model Reference:
|
Abc007
|
|
|
|
Blower Serial Number:
|
Abc007
|
|
|
|
Blower Power / Size:
|
2hp
|
|
|
|
CE/UKCA Mark:
|
Pass
|
|
|
|
Blower Distance:
|
Pass
|
1.5m
|
|
| Entrance, exits & evacuation | |||
|---|---|---|---|
|
The entrance or exit of an inflatable is important to ensure safe access and evacuation. It also has design features to help reduce the risks to users on the device. |
|||
|
Evacuation Time:
|
Pass
|
20Seconds
|
|
|
Is the device considered to be an enclosed unit?:
|
No
|
|
|
|
Does the device have a step?:
|
Yes
|
|
|
|
Adjacent Platform Height:
|
0.69m
|
|
|
|
Length of Step :
|
Pass
|
1.2m
|
1.2m
|
| Slides | |||
|---|---|---|---|
|
Slides are a particularly fun feature of an inflatable device and there are critical dimensions required to ensure safe operation. |
|||
|
Number of Slides:
|
1
|
|
|
|
Platform Height:
|
1.2m
|
|
|
|
Platform Wall Height:
|
Pass
|
0.7m
|
|
|
Slide Wall Height:
|
Pass
|
0.7m
|
|
|
Slide Sheet:
|
Pass
|
|
|
|
Run Out:
|
Pass
|
0.62m
|
.6m
|
|
Platform Roof Fitted:
|
Pass
|
|
|
|
Is the method of access to the slide using foam steps?:
|
Yes
|
|
|
| Users | |||
|---|---|---|---|
|
Understanding the height and number of users is vital to safe operation of an inflatable device. This should have been specified by the device manufacturer, but the inspector will check the manufacturers recommendations based on device dimensions and appropriate standards. |
|||
|
Max Number of Users of Height up to 1.0m:
|
10
|
|
|
|
Max Number of Users of Height up to 1.2m:
|
9
|
|
|
|
Max Number of Users of Height up to 1.5m:
|
7
|
|
|
|
Max Number of Users of Height up to 1.8m:
|
5
|
|
|
|
Custom Max User Height:
|
|
||
| Notes | |||
|---|---|---|---|
|
These are final notes sections for the relate to the report and are particularly important to pay attention to if present. Risk Assessments contain important operational information that must be noted and acted on to ensure safe play. Your inspector may also provide other Advisory Notes related to maintenance or operation over the next 12 months |
|||
|
Additional Notes:
|
Modifications done to pass include :
Width between step and slide .
Run out on slide
Extra anchor points.
|
|
|
|
Risk Assessment Notes:
|
|
||
|
Repairs needed to pass inspection:
|
|
||
|
Advisory items :
|
|
||
|
I confirm that this inflatable Bounce and Slide combo device has been inspected in accordance with the PIPA scheme rules, and where it is applicable, it meets the requirements of BS EN 14960. All details contained within this inspection report are a true representation of what I found and observed during my inspection process.
|
|
|
© 2026 The PIPA Testing Scheme Ltd. All Rights Reserved |